The light incubator is equipped with a fully automatic microcomputer control system, featuring a touch-sensitive interface for easy operation. It supports programmable multi-segment control, allowing independent settings for temperature, humidity, illumination, and time during both day and night cycles. The unit includes an air duct ventilation system that ensures gentle airflow and even temperature distribution throughout the chamber. The use of hollow reflective tempered glass enhances thermal insulation while providing an elegant and modern appearance. Additionally, the incubator offers a fully enclosed opaque lampshade, and optional features such as a studio power supply and disinfection device are available to meet various application needs.
Light Incubator Instructions:
1. For temperature control settings, please refer to the manual provided with the intelligent digital temperature controller.
2. To power on the incubator, turn on the main power switch. Once the power is connected, the power indicator light will illuminate, confirming that the system is operational.
3. This incubator is designed with a breakpoint protection function and a 90-second delay after the compressor stops before it restarts, ensuring stable performance and protecting the system from frequent cycling.
4. If lighting is required, simply activate the light switch. The lighting system can be used independently or in conjunction with the incubation process, depending on your needs.
Common Malfunctions and Solutions:
1. Frequent startups can reduce the lifespan of the equipment. To avoid this, ensure the incubator is not turned on and off unnecessarily.
2. In balanced mode, the compressor operates continuously, which improves cooling efficiency and helps maintain the compressor in optimal condition over time.
3. Uneven temperature distribution may occur if the items inside are too densely packed or if the internal circulating fan is not functioning properly. Ensure proper airflow by avoiding overloading and checking the fan regularly.
4. Prolonged use of the lighting system can cause the bulbs to heat up, leading to temperature imbalances within the chamber. It's recommended to use the lights only when necessary.
5. If the temperature inside the incubator becomes uneven, check the circulation system and ensure all vents are clear of obstructions.
6. During single-mode operation, the system will automatically adjust when the temperature drops below a set point. However, opening and closing the door frequently can cause significant temperature fluctuations, potentially causing the compressor to work harder than necessary.
7. If the compressor is not cooling properly, or if the internal temperature is uneven, check the condenser coils and ensure the air outlet is not frozen. Regular maintenance and cleaning are essential for optimal performance.