Bovine immunoglobulin G (IgG) elisa kit instructions

Bovine immunoglobulin G (IgG) elisa kit instructions

This reagent is for research purpose only: This kit is used to determine the content of immunoglobulin G (IgG) in bovine serum, plasma and related liquid samples. Shanghai Yanjin biological high-quality ELISA kit supplier, excellent quality, perfect after-sales. For more information, please call: 021-35301269 free test service.

Experimental principle:

This kit uses the double antibody sandwich method to determine the level of bovine immunoglobulin G (IgG) in the specimen. Coat the microplate with purified bovine IgG antibody to make a solid phase antibody, add immunoglobulin G (IgG) to the monoclonal antibody-coated microwells in turn, and then combine with HRP-labeled IgG antibody to form antibody-antigen Enzyme-labeled antibody complexes were washed thoroughly and added with substrate TMB for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the immunoglobulin G (IgG) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of bovine immunoglobulin G (IgG) in the sample was calculated by a standard curve.

Kit composition:

Kit composition

48 hole configuration

96-well configuration

save

Instructions

1 serving

1 serving

Sealing film

2 pieces (48)

2 pieces (96)

sealed bag

1

1

Enzyme coated plate

1 × 48

1 × 96

Store at 2-8 ℃

Standard product: 36 μg / ml

0.5ml × 1 bottle

0.5ml × 1 bottle

Store at 2-8 ℃

Standard dilution

1.5ml × 1 bottle

1.5ml × 1 bottle

Store at 2-8 ℃

Enzyme reagent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Sample diluent

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer A liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Developer B liquid

3 ml × 1 bottle

6 ml × 1 bottle

Store at 2-8 ℃

Stop solution

3ml × 1 bottle

6ml × 1 bottle

Store at 2-8 ℃

Concentrated washing liquid

(20ml × 20 times) × 1 bottle

(20ml × 30 times) × 1 bottle

Store at 2-8 ℃

Sample processing and requirements:

1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.

2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.

4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.

5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.

6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.

7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).

Steps

1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of standard products in the first and second wells, and then add standard products in the first and second wells 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 24μg / ml, 16μg / ml, 8μg / ml, 4μg / ml, 2μg / ml)

2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the test sample (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.

3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times (20 times of 48T) concentrated washing liquid with distilled water 30 times (20 times of 48T) and then use.

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.

10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.

Precautions:

1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.

3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.

4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).

5. The sealing film is limited to one-time use to avoid cross-contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined by the microplate reader.

8. All samples, washing liquids and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

10. If there is any difference with the English manual, the English manual shall prevail.

Calculation:

Taking the concentration of the standard as the abscissa and the OD value as the ordinate,

Draw a standard curve on coordinate paper, according to the OD of the sample

The value is determined by the standard curve; then multiplied by the dilution

Multiple; or calculate the standard using the concentration and OD value of the standard

The linear regression equation of the quasi-curve, the OD value of the sample

Substitute into the equation, calculate the sample concentration, and multiply by the dilution

The multiple is the actual concentration of the sample.

Kit performance:

1. The correlation coefficient R between the linear regression of the sample and the expected concentration is above 0.95.

2. The batch and approval shall be less than 9% and 11% respectively

examination range:

1.5μg / ml -30μg / ml

Storage conditions and validity period:

1. Store the kit: 2-8 ℃.

2. Validity: 6 months


Packaging cartons are made from paper products and are used to package various types of articles.Divided into a single pit (3) / double pit (5 layers) / three pits (7 layers), Carton subdivision cartons, color boxes, box and large-size odd-shaped beer boxes and other packaging. 

Cartons are low cost, easy to package, suitable for adding fillers, clean and other suitable products for factory packaging, transportationof goods, material finishing and so on.


Corrugated cardboard boxes have a wide range of uses. Corrugated paperboards are used as packaging materials and have low cost, light weight, and certain strength and stiffness. The Corrugated Carton is neat and beautiful in appearance, and can be printed with a variety of product designs and exquisite decorative advertisements. It can be produced using automatic lines with a high degree of mechanization. Waste cardboard can also be recycled. Therefore, in the packaging materials, corrugated board gradually replaced the board; corrugated boxes gradually replaced thewooden box. Corrugated carton packaging also saves valuable packaging materials such as metal and wood. Especially in the current situation in which the world`s wood resources are generally insufficient, it is of special significance. 


There are many products packed in corrugated boxes. There are canned foods, soft drinks or wine, food, meat, clothing and textiles, medicines, tobacco products, detergents, meters, hardware, electrical products, rubber products and countless other small commodities. In addition, for fragile products such as glassware, porcelain, enamelware, instruments, and heavier goods such as furniture, washing machines, televisions, refrigerators, bicycles, sewing machine heads and sewing machine panels, motorcycles, extra large seas Cotton mattresses, etc. can use corrugated boxes as packaging and shipping containers. In recent years, corrugated cartons have also been used for dry loading of difficult-to-transport goods such as fragile fresh eggs, live fish with water, flowers, fresh vegetables, fruits and fresh fish. This shows that corrugated cartons are used as packaging and loading materials, and their use is very broad.




Carton






Carton

Carton Box,Package Carton,Foldable Carton,Corrugated Carton

Shenzhen Yanhua Packing Products Co., Ltd. , https://www.yhpackagingbox.com