Golf course lighting design requirements

Due to the daytime temperatures and working life, many people like to arrange leisure activities at night, which makes the needs of the golf luminous stadium more and more important. We have done statistics. After a golf course added nighttime stadium functions, the number of players in the stadium increased by 16%, catering income increased by 5%, and the number of golfers on the court increased by 35%. Therefore, the adoption of the luminous stadium became more and more urgent.

高尔夫球场照明

Golf lighting design:

Although it is more and more important for the golf course to increase the luminous stadium, the existing luminescent stadium uses older lighting equipment, the distance between the light poles is unreasonable, and the poor surface treatment of the poles causes the illumination of the venue lights to attenuate quickly and become relatively dark. A series of problems affecting the playing quality and the ecological beauty of the golf course, such as the flickering of the fairway and the rust of the light pole. With the internationalization of the golf industry, more and more designers have absorbed the design concept of the international designer, making the effect of the luminous stadium. Like a more optimized direction.

1. Main tees: horizontal illuminance ≥ 120 lux, evenness Emin / Emax ≥ 0.5, Emin / Eave ≥ 0.7;

2. Second-seat table: The horizontal illuminance is not lower than the fairway average illuminance, evenness Emin / Emax ≥ 0.5, Emin / Eave ≥ 0.7;

3, the level of the fairway: horizontal illumination ≥ 70 lux, evenness Emin / Eave ≥ 0.35;

4. The vertical value of the fairway: vertical illuminance ≥ 10 lux (the centerline of the fairway);

5, green: horizontal illumination ≥ 200 lux, evenness Emin / Emax ≥ 0.6, Emin / Eave ≥ 0.7;

Illumination standards for golf courses:

Golf Lighting Standards Recommended by IESNA Among all sports-related lighting standards, only the IESNA RP-6-01 Sport Lighting Standard explicitly states the horizontal illumination lighting requirements for golf courses. But now it is not used.

The IESNA recommended illuminance level is: Level IV: Horizontal illuminance: (The illuminance reading should be measured at the same level.)

1. Serve area: 50 lx, CV= 0.25 or lower (Emax/Emin=3:1 or lower)

2. Fairways: 30 lx, CV = 0.35 or lower (Emax/Emin = 6:1 or lower)

3. Hole area: 50 lx, CV = 0.25 or lower (Emax/Emin = 3:1 or lower)

The illuminance at the tee, fairway, and green is measured using the illuminance at 1 meter; the vertical illuminance of the fairway measures the vertical illuminance of the fairway at a height of 25 meters; this lighting standard, except that the illuminance value is adjusted, the biggest change is the addition of The requirement of vertical illuminance, because it plays a key role in determining the ball's flight trajectory and landing point, this is a point that golf lighting system must consider, and it is the most easily overlooked point.